How to use it
Enter the air temperature and the dew point, as a METAR or a weather station gives them, to get the relative humidity. To go the other way, clear the dew point and enter the relative humidity instead. Switch units for °C. The dew point calculator uses the same formula, so the two always agree.
Relative humidity chart (°F)
| Temperature (°F) | Dew point 30 °F | Dew point 40 °F | Dew point 50 °F | Dew point 60 °F | Dew point 70 °F | Dew point 80 °F |
|---|---|---|---|---|---|---|
| 40 | 67% | 100% | – | – | – | – |
| 50 | 46% | 68% | 100% | – | – | – |
| 60 | 32% | 48% | 70% | 100% | – | – |
| 70 | 23% | 34% | 49% | 71% | 100% | – |
| 80 | 16% | 24% | 35% | 51% | 72% | 100% |
| 90 | 12% | 17% | 25% | 37% | 52% | 73% |
| 100 | 9% | 13% | 19% | 27% | 38% | 53% |
Relative humidity chart (°C)
| Temperature (°C) | Dew point -5 °C | Dew point 0 °C | Dew point 5 °C | Dew point 10 °C | Dew point 15 °C | Dew point 20 °C | Dew point 25 °C |
|---|---|---|---|---|---|---|---|
| 0 | 69% | 100% | – | – | – | – | – |
| 5 | 48% | 70% | 100% | – | – | – | – |
| 10 | 34% | 50% | 71% | 100% | – | – | – |
| 15 | 25% | 36% | 51% | 72% | 100% | – | – |
| 20 | 18% | 26% | 37% | 53% | 73% | 100% | – |
| 25 | 13% | 19% | 28% | 39% | 54% | 74% | 100% |
| 30 | 10% | 14% | 21% | 29% | 40% | 55% | 75% |
| 35 | 8% | 11% | 16% | 22% | 30% | 42% | 56% |
A dash is where the dew point would be above the temperature: the dew point can only equal the temperature or be below it.
What relative humidity is
Relative humidity is the vapour pressure of the water in the air as a percentage of the most it could hold at that temperature: RH = 100 × e ÷ es, as the National Weather Service writes it. The vapour pressure e is the saturation vapour pressure at the dew point, and es the saturation vapour pressure at the air temperature. When the two temperatures meet, the air is saturated and the humidity is 100%.
Because es rises quickly with temperature, the relative humidity falls as the day warms even when the moisture in the air, and so the dew point, stays the same. At a dew point of 10 °C, the humidity is 100% at 10 °C, 53% at 20 °C and 29% at 30 °C. That is why the dew point is the better measure of how much moisture there is.
The formula
The saturation vapour pressure is from the Magnus formula with the constants of Alduchov and Eskridge (1996), as Lawrence (2005, Bulletin of the American Meteorological Society) recommends them: es = 6.1094 × exp(17.625 × T ÷ (243.04 + T)) hPa, with T in °C, within 0.4% from −40 to 50 °C. So RH = 100 × exp(17.625 × Td ÷ (243.04 + Td) − 17.625 × T ÷ (243.04 + T)), and solved the other way, dew point = 243.04 × γ ÷ (17.625 − γ) with γ = ln(RH ÷ 100) + 17.625 × T ÷ (243.04 + T).
Checked against the National Weather Service formula
The NWS weather calculator uses the older form es = 6.11 × 10^(7.5 × T ÷ (237.3 + T)) hPa. Its pages publish the formula but no worked examples, so the check below runs both formulas on the same figures:
| Temperature (°C) | Dew point (°C) | RH, this calculator | RH, NWS formula | Difference (points) |
|---|---|---|---|---|
| 35 | 25 | 56.28% | 56.34% | −0.06 |
| 30 | 20 | 55.08% | 55.11% | −0.03 |
| 25 | 15 | 53.83% | 53.84% | 0.00 |
| 20 | 10 | 52.54% | 52.52% | +0.02 |
| 10 | 5 | 71.09% | 71.04% | +0.05 |
| 0 | -5 | 69.06% | 68.96% | +0.10 |
| -20 | -25 | 64.38% | 64.14% | +0.24 |
From 0 to 50 °C the two never differ by more than 0.13 percentage points, and from −40 to 50 °C by no more than 0.43.
Humidity from a METAR
A METAR gives the temperature and dew point in whole degrees Celsius, so each could be up to half a degree off. US METARs from automated stations usually also carry both to the tenth of a degree in the remarks, as a T group: T00261015 is 2.6 °C and a dew point of −1.5 °C (FAA Order JO 7900.5, Federal Meteorological Handbook No. 1). With that group, use the tenths and most of the rounding below goes away. At 20 °C and a dew point of 10 °C the calculator gives 53%, but the true figures could be anywhere from 20.5 and 9.5 °C (49%) to 19.5 and 10.5 °C (56%). Treat humidity worked from the whole degrees alone as good to a few percent.
Training and planning aid only. For any flight, take performance from the aircraft's POH or AFM and weather from official sources, and check every figure yourself.