The lapse rates
| Lapse rate | Per 1,000 ft | What it describes |
|---|---|---|
| Dry adiabatic | 3 °C (5.4 °F) | Unsaturated air cooling as it is lifted, with no heat exchanged |
| Standard (ISA) | 1.98 °C (3.57 °F), rounded to 2 °C (3.5 °F) | The temperature fall with height in the standard atmosphere, up to 36,089 ft; above that the temperature stays the same |
The FAA Glider Flying Handbook gives the dry adiabatic lapse rate as 3 °C or 5.4 °F per 1,000 ft, and National Weather Service forecaster training gives the same 3 °C per 1,000 ft. The standard lapse rate is that of the ICAO standard atmosphere, 6.5 °C per kilometre, which the same FAA glossary rounds to 2 °C (3.5 °F) per 1,000 ft.
Dry and saturated air
The standard lapse rate is the one the standard atmosphere uses to define pressure and density altitude; the dry adiabatic rate is how fast lifted unsaturated air cools. Saturated air cools more slowly as it rises, at a rate that varies with temperature, so this calculator does not give one figure for it.
Air density
Density is pressure ÷ (R × absolute temperature). Lower pressure and higher temperature both mean thinner air. The density altitude expresses that density as the altitude in the standard atmosphere where it is found. For the standard atmosphere at each height, use the standard atmosphere calculator.
Density at standard conditions
| Pressure altitude (ft) | ISA temperature | Density (kg/m³) | Density ratio |
|---|---|---|---|
| 0 | 15.0 °C | 1.2250 | 1.0000 |
| 2,000 | 11.0 °C | 1.1549 | 0.9428 |
| 4,000 | 7.1 °C | 1.0879 | 0.8881 |
| 6,000 | 3.1 °C | 1.0239 | 0.8359 |
| 8,000 | -0.8 °C | 0.9629 | 0.7860 |
| 10,000 | -4.8 °C | 0.9046 | 0.7385 |
Training and planning aid only. For any flight, take performance from the aircraft's POH or AFM and weather from official sources, and check every figure yourself.